FM Transmitter Measurement Report
Created: 2023-05-30 18-32-15
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
101.50 MHz |
5/5, 79 dBuV |
RIRE & |
Pilot |
RDS |
Phase
Difference |
7.1 kHz |
3.5 kHz |
54 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
0,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 75,0
kHz |
8 kHz |
64 kHz |
17059 |
0,0352 |
|
Modulation Power
Limit |
Measuring
Tolerance |
8,0 dBr |
0,0 dBr |
MIN |
AVE |
MAX |
% above
8,0 dBr |
4,1 dBr |
6,12 dBr |
7,3 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
" RIRE & " |
F226 |
0 (No PTY) |
1 |
0 |
1 |
2 |
18:32, 30.05.2023 |
RT |
"RIRE : L APPEL TROP CON DE R&C " |
AF |
EON |
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz |
- |
|
|